Publication Type : Conference Paper
Publisher : Proceedings of IEEE International Conference on Industrial Technology
Source : Proceedings of IEEE International Conference on Industrial Technology 2000 (IEEE Cat. No.00TH8482), IEEE (2000)
Url : http://ieeexplore.ieee.org/abstract/document/854243/
ISBN : 9780780358126
Accession Number : 6715807
Keywords : asynchronous generators, double output wound rotor induction generators, doubly wound cage induction generator, Electric power generation, field performance estimation, Gears, Induction generators, load flow, Performance evaluation, Permanent magnet generator, permanent magnet generators, Permanent magnets, power flow models, Power generation, rotors, squirrel cage induction generator, wind electric generator, Wind energy generation, Wind power generation, Wind turbines, Wounds
Campus : Coimbatore
School : School of Engineering
Department : Electrical and Electronics
Year : 2000
Abstract : Four options of wind electric generator (WEG) technology have been studied and compared based on their estimated field performance. The electric generators considered are squirrel cage induction generator (IG), doubly wound cage IG, double output wound rotor IG and permanent magnet generator (PMG). The performance evaluation has been done by developing power flow models of the WEGs. The results highlight the relatively superior performance efficiency of WEGs employing doubly wound IG and double output IG.
Cite this Research Publication : K. K. Sasi and Basu, S., “Technology options for utility grade electric power generation from wind”, in Proceedings of IEEE International Conference on Industrial Technology 2000 (IEEE Cat. No.00TH8482), 2000.