Publisher : Indian Journal of Anaesthesia, Indian Society of Anaesthetists,
Source : Indian Journal of Anaesthesia, Indian Society of Anaesthetists, Volume 61, Number 3, p.230-234 (2017)
Campus : Kochi
School : School of Medicine
Department : Anaesthesiology
Year : 2017
Abstract : {Background and Aims: Obese individuals are predisposed to difficult airway and intubation. They usually yield confusing or misleading auscultatory findings. We aimed to assess the rapidity and efficacy of ultrasonographic (USG) sliding lung sign for confirming endotracheal intubation in normal as well as overweight and obese surgical patients. Methods: This prospective, observational study was performed in forty surgical patients. Twenty patients with body mass index (BMI) 25 were recruited to Group A, whereas twenty patients with BMI ≥25 constituted Group B. Following induction and intubation, appearance of end‑tidal carbon dioxide waveform was used to confirm endotracheal intubation. Presence of breath sounds bilaterally was sought by auscultation, and time taken for auscultatory confirmation was noted. The USG confirmation of air entry to the lung field as indicated by lung sliding was sought, and the time taken was noted. Chi‑square test, independent t‑test and paired t‑test were used as applicable. Results: Auscultatory confirmation was more rapid in Group A as compared to Group B (9.34 ± 2.43 s vs. 14.35 ± 5.53 s
Cite this Research Publication : S. Rajan, Surendran, J., Paul, J., and Kumar, L., “Rapidity and efficacy of ultrasonographic sliding lung sign and auscultation in confirming endotracheal intubation in overweight and obese patients”, Indian Journal of Anaesthesia, vol. 61, pp. 230-234, 2017.