Back close

Influence of System Parameters on the Hysteresis Characteristics of a Horizontal Rijke Tube

Publication Type : Journal Article

Publisher : International Journal of Spray and Combustion Dynamics

Source : International Journal of Spray and Combustion Dynamics , Volume 6, Number 3, p.293-316 (2014)

Url : http://scd.sagepub.com/content/6/3/293.short

Keywords : Hysteresis, period-2 oscillations, Rijke tube, Subcritical Hopf bifurcation

Campus : Coimbatore

School : School of Engineering

Center : Computational Engineering and Networking

Department : Mechanical Engineering

Year : 2014

Abstract : The influence of system parameters such as heater power, heater location and mass flow rate on the hysteresis characteristics of a horizontal Rijke tube is presented in this paper. It is observed that a hysteresis zone is present for all the mass flow rates considered in the present study. A power law relation is established between the non-dimensional hysteresis width and the Strouhal number, defined as the ratio between convective time scale and acoustic time scale. The transition to instability in a horizontal Rijke tube is found to be subcritical in all the experiments performed in this study. When heater location is chosen as the control parameter, period-2 oscillations are found for specific values of mass flow rate and heater power

Cite this Research Publication : Dr. E. A. Gopalakrishnan and Sujith, R. I., “Influence of System Parameters on the Hysteresis Characteristics of a Horizontal Rijke Tube”, International Journal of Spray and Combustion Dynamics , vol. 6, pp. 293-316, 2014.