Back close

Experimental and computational analysis of a row of three co-swirling impinging flames

Publication Type : Journal Article

Publisher : Heat and Mass Transfer/Waerme- und Stoffuebertragung

Source : Heat and Mass Transfer/Waerme- und Stoffuebertragung, Springer Verlag, Volume 56, Issue 2, p.365-384 (2020)

Url : https://www2.scopus.com/inward/record.uri?eid=2-s2.0-85070065613&doi=10.1007%2fs00231-019-02706-x&partnerID=40&md5=75327bb6925eba481ddc30752365ecf9

Keywords : Coimbatore, Computational analysis, funding_text 1=Authors sincerely acknowledge financial support received from Dr. B.R. Ambedkar National Institute of Technology Jalandhar for the execution of this experimental study. The author is also indebted to the faculty at Amrita Vishwa Vidyapeet, Heat conduction, Heat flux, Heat flux distributions, Heat transfer characteristics, Impingement heat transfer, INDIA for their support and encouragement., Inverse heat conduction, Pressure distribution, Recirculation zones, Separation distances, Strong interaction

Campus : Coimbatore

School : School of Engineering

Department : Mechanical Engineering

Year : 2020

Abstract : Detailed flow field and heat transfer characteristics developed in a row of three co-rotating dual swirling impinging flames have been investigated experimentally as well as numerically. Impingement heat transfer and pressure distribution has been studied experimentally at different separation distances and inter-jet spacings. Inverse heat conduction procedure (IHCP) has been used for estimating heat fluxes on the front side of impingement plate. Turbulence induced mixing results in strong interactions amongst adjacent flames causing deflections of inner flames of the burners situated at sides of central burner. Numerical simulation predicted formation of asymmetric recirculation zones for side flames. Symmetric interactions taking place for central flame produced two equal recirculation lobes for central flame. Behavior of central inner flame has been observed to be dependent on the value of inter-jet spacing used. Suppression of central inner flame tend to occur at higher inter-jet spacings due to recirculating products. Impingement pressure distribution is observed to be consistent with the heat flux distribution. Averaged heat fluxes registered at the impingement plate due to the central flame are higher in magnitude to those pertaining to each of the side flames.

Cite this Research Publication : P. Singh, Dr. Ratna Kishore V., and Chander, S., “Experimental and Computational Analysis of a Row of Three Co-swirling Impinging Flames”, Heat and Mass Transfer/Waerme- und Stoffuebertragung, vol. 56, no. 2, pp. 365-384, 2020.