Back close

Distribution entropy (DistEn): A complexity measure to detect arrhythmia from short length RR interval time series

Publication Type : Conference Paper

Publisher : IEEE

Source : 37th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), 2015, DOI: 10.1109/EMBC.2015.7319565

Url : https://ieeexplore.ieee.org/document/7319565

Campus : Amritapuri

School : School for Sustainable Futures

Center : Amrita Center for Wireless Networks and Applications (AmritaWNA)

Year : 2015

Abstract : Heart rate complexity analysis is a powerful non-invasive means to diagnose several cardiac ailments. Non-linear tools of complexity measurement are indispensable in order to bring out the complete non-linear behavior of Physiological signals. The most popularly used non-linear tools to measure signal complexity are the entropy measures like Approximate entropy (ApEn) and Sample entropy (SampEn). But, these methods become unreliable and inaccurate at times, in particular, for short length data. Recently, a novel method of complexity measurement called Distribution Entropy (DistEn) was introduced, which showed reliable performance to capture complexity of both short term synthetic and short term physiologic data. This study aims to i) examine the competence of DistEn in discriminating Arrhythmia from Normal sinus rhythm (NSR) subjects, using RR interval time series data; ii) explore the level of consistency of DistEn with data length N; and iii) compare the performance of DistEn with ApEn and SampEn. Sixty six RR interval time series data belonging to two groups of cardiac conditions namely `Arrhythmia' and `NSR' have been used for the analysis. The data length N was varied from 50 to 1000 beats with embedding dimension m = 2 for all entropy measurements. Maximum ROC area obtained using ApEn, SampEn and DistEn were 0.83, 0.86 and 0.94 for data length 1000, 1000 and 500 beats respectively. The results show that DistEn undoubtedly exhibits a consistently high performance as a classification feature in comparison with ApEn and SampEn. Therefore, DistEn shows a promising behavior as bio marker for detecting Arrhythmia from short length RR interval data.

Cite this Research Publication : Chandan Karmakar, Radhagayathri K Udhayakumar, and Marimuthu Palaniswami, Distribution entropy (DistEn): A complexity measure to detect arrhythmia from short length RR interval time series, 37th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), 2015, DOI: 10.1109/EMBC.2015.7319565

Admissions Apply Now