Back close

FLOW ANALYSIS of ISOBUTANE (R-600A) INSIDE AN ADIABATIC CAPILLARY TUBE

Publisher : IOP Conference Series: Materials Science and Engineering

Campus : Bengaluru

School : School of Engineering

Department : Mechanical

Year : 2018

Abstract : Capillary tubes are simple narrow tubes but the phase change which occurs inside the capillary tubes is complex to analyze. In the present investigation, an attempt is made to analyze the flow of Isobutane (R-600a) inside the coiled capillary tubes for different load conditions by Homogeneous Equilibrium Model. The Length and diameter of the capillary tube not only depend on the pressure and temperature of the condenser and evaporator but also on the cooling load. The present paper investigates the change in dimensions of the coil capillary tube with respect to the change in cooling load on the system for the constant condenser and evaporator conditions. ANSYS CFX (Central Florida Expressway) software is used to study the flow characteristics of the refrigerant. Appropriate helical coil is selected for this analysis.

Admissions Apply Now