Publication Type : Journal Article
Publisher : Institution of Engineers (India)- EN
Source : Institution of Engineers (India)- EN, Volume 91, Issue 1, p.20-26 (2010)
Url : http://slim.spce.ac.in/W27/Result/Dtl/W21OneItem.aspx?xC=034588
Keywords : Activated sludge process, Aeration, Dimensional analysis, Froude number, Overall oxygen transfer factor, Package plants, Plunging hollow jet aerator
Campus : Coimbatore
School : School of Engineering
Department : Civil
Year : 2010
Abstract : Plunging hollow jet aerators consist of a cone, which deflects water at the end of a discharging pipe through the annular opening forming a hollow jt on the water surface, thus creating high turbulence and entaring large quantities of air. The effciency E of the device was high ( .5 kg./kWh) for the small opening between the pipe and the cone. The significance of the present work is that, the results are expressed by a graph between the non-dimensional variables. the gap between the cone and the pipe; K L A, the overall transfer factor and Q is the discharge. In addition, the non-dimensuional quantity 'E s' involiving efficiency could be expressed as a function of F 1. the graphs allow the extension of results to a wide range of sizes.
Cite this Research Publication : Dr. Mini K. M., .G.Kaimal, M., and N Pillai, N., “Study of Plunging Hollow-jet Aerators using Non-dimensional Parameters”, Institution of Engineers (India)- EN, vol. 91, no. 1, pp. 20-26, 2010.