Harmonic Reduction Analysis for Electric Arc Furnace using Passive Filters and DSTATCOM

Publication Type : Journal Article

Publisher : International Journal of Engineering and Advanced Technology (IJEAT)

Source : International Journal of Engineering and Advanced Technology (IJEAT), Volume 8, Issue 6 (2019)

Url : https://www.ijeat.org/wp-content/uploads/papers/v8i6/F8206088619.pdf

Campus : Bengaluru

School : School of Engineering

Department : Electrical and Electronics

Year : 2019

Abstract : The Industrial furnaces are used globally for wide range of applications from lab scale to complete production lines. They provide continuous high temperatures of 300°C to 3000°C with precise control of temperature and material flow to ensure consistent and uniform output. The furnace operators that deliver at higher efficiencies are prone to power supply system challenges with greater potential for power quality implications on supply system. Hence such operators of high intensity power furnaces should consider design and development of appropriate mitigation techniques to upgrade the power supply quality. In this paper the mitigation of harmonics in Electric Arc Furnace is dealt with suitable passive filter and DSTATCOM techniques. Also, the performance analysis of Electric Arc Furnace has been carried out with MATLAB/SIMULINK based model using Sinusoidal pulse width modulation, hysteresis and the sliding mode controllers.

Cite this Research Publication : Priyashree S. and Vidya H. A., “Harmonic Reduction Analysis for Electric Arc Furnace using Passive Filters and DSTATCOM”, International Journal of Engineering and Advanced Technology (IJEAT), vol. 8, no. 6, 2019.